Send Email
Send SMS
Search
Anamol Laboratories Private Limited
Anamol Laboratories Private Limited


Biochemistry Reagent

Providing you the best range of uric acid chemistry reagent, acid phosphatase reagent kinetic method, alkaline phosphatase, calcium o-cpc method clinical chemistry reagent, phosphorous clinical chenistry reagent and anamol albumin clinical chemistry reagent with effective & timely delivery.

Uric Acid Chemistry Reagent

REQUEST CALLBACK

Uric Acid Chemistry Reagent
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 800 / KitGet Latest Price

Product Details:
Minimum Order Quantity50 Kit
Accuracy99%
Model NumberUA-46
BrandAnamol
Packaging TypeBox
ClassificationBiochemical Reagents
Packaging Size50ml/200ml

The uric acid blood test is used to detect high levels of this compound in the blood in order to help diagnose gout. The test is also used to monitor uric acid levels in people undergoing chemotherapy or radiation treatment for cancer. Rapid cell turnover from such treatment can result in an increased uric acid level. The uric acid urine test is used to help diagnose the cause of recurrent kidney stones and to monitor people with gout for stone formation. Uric Acid can be estimated in serum / plasma using Uricase method.


Additional Information:

  • Item Code: UA-65
  • Delivery Time: 10-15 days
  • Packaging Details: 50ml/200ml
Yes! I am Interested

Acid Phosphatase Reagent Kinetic Method

REQUEST CALLBACK

Acid Phosphatase Reagent Kinetic Method
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 200 / PackGet Latest Price

Product Details:
Minimum Order Quantity50 Pack
Accuracy99%
Linearity75 IU/L
No. Of ReagentsLyophilized Substrate With Ready-To-Use Buffer
Packaging TypeBottle
Physical StateLiquid
Test Time Required360 Second

ACID PHOSPHATASE

Acid Phosphatase is an enzyme produced by the prostate gland. It may be found in increased amounts in men who have prostate cancer or other diseases. Elevations of total enzyme activity are also observed in case of myeloma, thrombocytopenia and some liver diseases. Test for the estimation of Acid Phosphatase activity is done in serum / plasma using α-Napthylphosphate kinetic method.

Features
  •   Kinetic Method Using α-Nephthyl Phosphate Substrate
  •  Two Reagents With Easy Preparation
  •  Working Reagent Stable For One Week
  •  Freedom To Test Total Or Nonprostatic Acid Phosphatase
  •  Fast Result
  •  High Linearity
  •  Suitable For Fully Automated Chemistry Analyzer
Specifications

 

  •  Methodology - Nephthyl Phosphate - Fast Red TR
  •  No. Of Reagents - Lyophilized Substrate With Ready-To-Use Buffer
  •  Shelf Life - 24 Months
  •  Sample Volume Required - 0.1 ML
  •  Test Time Required - 6 Minutes
  •  Linearity - 75 IU/L
  •  Automation - Enabled


Additional Information:

  • Item Code: ACC-4546
  • Delivery Time: 10-15 days
  • Packaging Details: Pack Size: 12 x 1 ML 1 x 50 ML
Yes! I am Interested

Alkaline Phosphatase

REQUEST CALLBACK

Alkaline Phosphatase
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1,500 / KitGet Latest Price

Product Details:
Minimum Order Quantity50 Kit
Model NumberAFR-522
BrandAnamol
TypeBiochemistry Reagent
Packaging TypeBox then into carton
Packaging SizePack Size-20 - 4 X 5ML 50 - 5 X 10 ML
Sample Volume Required20 ml
Grade StandardLaboratory
No. Of ReagentTwo reagent

ALKALINE PHOSPHATASE

 

INTENDED USE: Test for estimation of Alkaline Phosphatase activity in serum / plasma using PNPP method.

 

Introduction:

Alkaline phosphatase levels are of interest in the diagnosis of hepatobiliary disorders and bone diseases associated with increased osteoblastic activity. Moderate elevations of Alkaline Phosphatase may be seen in Hodgkin’s Disease, congestive heart failure, ulcerative colitis, regional enteritis and intra-abdominal bacterial infections. Alkaline Phosphatase activity can be tested in serum / plasma using PNPP kinetic method.

 

Features:

· Kinetic Method Using PNPP Substrate

· Two Reagents With Easy Preparation

· Working Reagent Stable For Three Weeks

· Fast Result

· High Linearity (2000 IU/L)

· Suitable For Fully Automated Chemistry Analyzer

·

Specification

· Kinetic Method Using PNPP Substrate

· Available in both AMP as well as DEA buffer

· Sample volume required – 20 µl

· Two Reagents With Easy Preparation (Tablet + Buffer)

· Working Reagent Stable For Three Weeks

· Fast Result

· High Linearity (2000 IU/L)

· Suitable For Fully Automated Chemistry Analyzer



Additional Information:

  • Item Code: AFC-141
  • Production Capacity: 600 mn ml per annum.
  • Delivery Time: 10-15 Days
  • Packaging Details: Kit dimensions: 20 ML – 85x105x45 mm 50 ML – 85x105x45 mm Approx weight of kit: 20- 4 X 5 ML - 77 gms 50 - 5X10 ML - 86 gms No of kits in shipper: 20- 4 X 5 ML - 92 50 - 5X10 ML - 92 Dimension of shipper: 410x550x378 mm Approx weight of shipper: 20- 4 X 5 ML – 10 Kg 50 - 5X10 ML – 11 Kg
Yes! I am Interested

Calcium O-CPC Method Clinical Chemistry Reagent

REQUEST CALLBACK

Calcium O-CPC Method Clinical Chemistry Reagent
  • Calcium O-CPC Method Clinical Chemistry Reagent
  • Calcium O-CPC Method Clinical Chemistry Reagent
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 600 / KitGet Latest Price

Product Details:
Minimum Order Quantity50 Kit
Model NumberCCPC-152
BrandAnamol
Packaging Size2X25 ML 2X100 ML
Linearity15 mg/dL
No. Of Reagent- Two Liquids Ready-To-Use

CALCIUM CPC

 

INTENDED USE: Test for estimation of Calcium in serum / plasma using O-CPC method.

 

Introduction:

Calcium plays an active physiological role in bone mineralisation, neuromuscular excitability, muscle contraction, and blood coagulation. Hypocalcemia can result from chronic renal failure with hypoproteinemia and hyperphosphatemia, or hypoparathyroidism, or vitamin D deficiency (osteomalacia, rickets). The most common cases of hypercalcemia are associated with hyperparathyroidism, tumours and bone metastases, hyperthyroidism or vitamin D overdose. Calciuria has little practical value in the various diagnoses except for the renal tubulopathies. Calcium can be estimated in serum / plasma using o-Cresolphthalein Complexone method.

 

Features:

· O-Cresolphthlein Complexone Specific To Calcium

· Fe And Mg Intereference Eliminated

· Liquid Stable Reagents With Long Shelf Life

· Fast Result

· High Linearity

· Suitable For Fully Automated Chemistry Analyzer

 

Specification:

· Methodology - o-CPC

· No. Of Reagents - Two Liquids Ready-To-Use

· Shelf Life - 24 Months

· Sample Volume Required – 20 µL

· Test Time Required - 5 Minutes

· Linearity - 15 mg/dL

· Automation - Enabled



Additional Information:

  • Item Code: CCPC-55
  • Production Capacity: 600 mn ml per annum.
  • Delivery Time: 10-15 Days
  • Packaging Details: Kit dimensions: 2X25 ML - 85x105x45 mm 2X100 ML - 105x55x145 mm Approx weight of kit: 1X25 ML - 92 gms 2X50ML - 185 gms No of kits in shipper: 1X25 ML - 92 2X50 ML - 92 Dimension of shipper: 410x550x378 mm Approx weight of shipper: 1 X 25 ML – 8 kgs 2 X 50 ML – 20 kgs
Yes! I am Interested

Phosphorous Clinical Chenistry Reagent

REQUEST CALLBACK

Phosphorous Clinical Chenistry Reagent
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1,200 / KitGet Latest Price

Product Details:
Minimum Order Quantity50 Kit
Model NumberPCCR-575
BrandAnamol
Packaging Size20ml/100ml
Sample Volume Required20mg/dl
No. Of ReagentSingle Reagent

PHOSPHORUS

 

INTENDED USE: Test for estimation of PHOSPHORUS in serum / plasma using UV END POINT method.

 

Introduction:

The Inorganic phosphate is the fraction of clinical interest since its levels are closely tied to bone metabolism, renal function, vitamin D levels and parathyroid hormone status. Phosphorus can be estimated in serum / plasma using Phospho Molybdate method.

 

Feature:

·      Method Specific To Phosphorus Inorganic

·      Liquid Stable Reagent With Long Shelf Life

·      Fast Result

·      High Linearity

·      Suitable For Fully Automated Chemistry Analyzer

 

Specification:

·      Methodology - Phosphomolybdate- UV

·      No. Of Reagents - Single Ready-To-Use

·      Shelf Life - 24 Months

·      Sample Volume Required – 10 µL

·      Test Time Required - 5 Minutes

·      Linearity - 20 mg/dL

·      Automation - Enabled



Additional Information:

  • Item Code: DSJ-455
  • Delivery Time: 10-15 days
  • Packaging Details: 20ml/100ml
Yes! I am Interested

Anamol Albumin Clinical Chemistry Reagent

REQUEST CALLBACK

Anamol Albumin Clinical Chemistry Reagent
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 200 / BoxGet Latest Price

Product Details:
Minimum Order Quantity50 Box
Model NumberACC-485
BrandAnamol
Packaging SizePack Size 2X100 ML 2X500 ML
Sample Volume Required10ml
No. Of ReagentSingle reagent ready to use

Albumin levels indicate the overall health status of an individual. Albumin levels decrease in severe liver disease, malabsorption, diarrhea, eclampsia and nephrosis. The level is increased in dehydration. Albumin can be estimated in serum / plasma using BCG method.
Features
  •  BCG Method Specific For Human Albumin
  •  Liquid Stable Reagent With Long Shelf Life
  •  Fast Result
  •  High Linearity
  •  LCF (Lipid Clearing Factor) Incorporated For Lipamic Sample
  •  Suitable For Fully Automated Chemistry Analyzer
Specifications
  •  Methodology - Bromocresol Green
  •  No. Of Reagents - Single Ready-To-Use
  •  Shelf Life - 24 Months
  •  Sample Volume Required - 0.01 ML
  •  Test Time Required - 1 Minutes
  •  Linearity - 6 GM/DL
  •  Automation - Enabled


Additional Information:

  • Item Code: ABR-2645
  • Delivery Time: 10-15 days
  • Packaging Details: Pack Size: 2X100 ML 2X500 ML
Yes! I am Interested

Calcium ARS III Biochemistry Reagent/Calcium Arsenazo III Clinical Chemistry Reagent

REQUEST CALLBACK

Calcium ARS III Biochemistry Reagent/Calcium Arsenazo III Clinical Chemistry Reagent
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 300 / BoxGet Latest Price

Product Details:
Minimum Order Quantity50 Box
BrandAnamol
Packaging Size1X25 ML 2X50 ML
UsageLaboratory

                                                            CALCIUM ARS III

 

INTENDED USE: Test for estimation of Calcium  in serum / plasma using Arsenazo method.

 

Introduction:

Calcium plays an active physiological role in bone mineralisation, neuromuscular excitability, muscle contraction, and blood coagulation. Hypocalcemia can result from chronic renal failure with hypoproteinemia and hyperphosphatemia, or hypoparathyroidism, or vitamin D deficiency (osteomalacia, rickets). The most common cases of hypercalcemia are associated with hyperparathyroidism, tumours and bone metastases, hyperthyroidism or vitamin D overdose. Calciuria has little practical value in the various diagnoses except for the renal tubulopathies. Calcium can be estimated in serum / plasma using Arsenazo III method.

 

Features:

·       Arsenazo III Specific To Calcium

·       Fe And Mg Intereference Eliminated

·       Thermostable Single Liquid (25 0C) With Long Shelf Life

·       Fast Result

·       High Linearity

·       Interference From Icteric & Hemolyzed Samples Eliminated

·       Suitable For Fully Automated Chemistry Analyzer

 

Specification

·       Methodology - Arsenazo III

·       No. Of Reagents - Single Liquid Ready-To-Use

·       Shelf Life - 24 Months

·       Sample Volume Required – 20 µL

·       Test Time Required - 2 Minutes

·       Linearity - 16 mg/dL

·       Automation - Enabled



Additional Information:

  • Item Code: CA-475
  • Production Capacity: 600 mn ml per annum.
  • Delivery Time: 10-15 Days
  • Packaging Details: Kit dimensions: 1X25 ML - 85x105x45 mm 2X50 ML - 85x105x45mm Approx weight of kit: 1X25 ML - 50 gms 2X50ML - 185 gms No of kits in shipper: 1X25 ML - 92 2X50 ML - 92
Yes! I am Interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Anamol Laboratories Private Limited
Madhu M (Sales & Marketing)
61, Phase 1, Genesis Industrial Township Kolgaon, Near Mumbai, Nerul,
Palghar - 401404, Maharashtra, India
Call Us: 
Call Response Rate: 71%
Share Us :
F G T L



Home  |   About Us   |  Our Product Range  |  Site Map  |   Contact Us